2,187
edits
(→HBA and SAN Operations: Added "Emulex") |
(→HBA and SAN Operations: Added "QLogic") |
||
Line 356: | Line 356: | ||
# Download new firware version to each HBA | # Download new firware version to each HBA | ||
#* EG <code>/usr/sbin/hbanyware/hbacmd download 10:00:00:00:c9:82:97:9e zf280a4.all</code> | #* EG <code>/usr/sbin/hbanyware/hbacmd download 10:00:00:00:c9:82:97:9e zf280a4.all</code> | ||
==== EMCgrab Collection ==== | ==== EMCgrab Collection ==== | ||
Line 368: | Line 367: | ||
#* EG <code>./emcgrab.sh</code> | #* EG <code>./emcgrab.sh</code> | ||
# Results can be found in <code>\emcgrab\outputs</code> folder | # Results can be found in <code>\emcgrab\outputs</code> folder | ||
=== QLogic === | |||
==== Find QLogic HBA Driver and Firmware Version ==== | |||
# <code> cd /proc/scsi/qla2300 </code> | |||
# <code> more 1 </code> for HBA 1 | |||
<pre> | |||
[root@uklonesxp1 qla2300]# more 1 | |||
QLogic PCI to Fibre Channel Host Adapter for QLA2340 : | |||
Firmware version: 3.03.19, Driver version 7.07.04 | |||
Entry address = 0x7dc314 | |||
HBA: QLA2312 , Serial# E79916 | |||
Request Queue = 0x3f403000, Response Queue = 0x3f414000 | |||
... | |||
</pre> | |||
==== Install QLogic HBA Utility ==== | |||
Installation instructions for the SANsurfer utility | |||
# Put the downloaded tgz file on the UKLONVCP1 NFS Share, eg scli-1.7.0-12.i386.rpm.gz | |||
# Copy to folder /var/updates (create if it doesn't exist) | |||
#* <code> cp /vmfs/volumes/UKLONVCP1\ NFS\ Share/scli-1.7.0-12.i386.rpm.gz /var/updates </code> | |||
# Uncompress the file with the following command; | |||
#* <code> gunzip scli-1.7.0-12.i386.rpm.gz </code> | |||
# Enter the following commands to install the package, and then check its installed; | |||
#* rpm -iv scli-1.7.0-12.i386.rpm | |||
#* rpm -q scli | |||
<pre> | |||
[root@uklonesxp1 updates]# rpm -iv scli-1.7.0-12.i386.rpm | |||
Preparing packages for installation... | |||
scli-1.7.0-12 | |||
[root@uklonesxp1 updates]# rpm -q scli | |||
scli-1.7.0-12 | |||
</pre> | |||
==== Update QLogic HBA Firmware ==== | |||
See QLogic website for latest version, you must ensure the firmware version is compatible with the current running driver version. Requires SANsurfer to be installed 1st (see above) | |||
# Put the downloaded tgz file on the UKLONVCP1 NFS Share, eg q231x_234x_bios147.zip, and unzip to folder | |||
# Create a new folder for the update; | |||
#* <code> mkdir /var/updates/q231x_234x_bios147 | |||
# Copy the firmware onto the ESX server; | |||
#* <code> cp /vmfs/volumes/UKLONVCP1\ NFS\ Share/q231x_234x_bios147/QL23ROM.BIN /var/updates/q231x_234x_bios147/ </code> | |||
# Move to the folder containing the update; | |||
#* <code> cd /var/updates/q231x_234x_bios147/ </code> | |||
# Start the SANsurfer utility | |||
#* <code> scli </code> | |||
# Go into the '''HBA Utilities''' option | |||
# Select the '''Save Flash'' option | |||
# Follow the prompts to save the flash to a backup file, eg BackupROM.bin | |||
# Select the '''Update Flash''' option | |||
# Follow the prompts to update the flash, using the file copied to the ESX, eg QL23ROM.BIN | |||
<pre> | |||
Enter a file name or Hit <RETURN> to abort: QL23ROM.BIN | |||
Updating flash on HBA 0 - QLA2340 . Please wait... | |||
Option ROM update complete. Changes have been saved to the HBA 0. | |||
Please reboot the system for the changes to take effect. | |||
Updating flash on HBA 1 - QLA2340 . Please wait... | |||
Option ROM update complete. Changes have been saved to the HBA 1. | |||
Please reboot the system for the changes to take effect. | |||
</pre> | |||
== Netflow == | == Netflow == |