ESX Baseline Dec 08: Difference between revisions
Jump to navigation
Jump to search
m (5 revisions) |
m (Added NOINDEX) |
||
Line 1: | Line 1: | ||
__NOINDEX__ | |||
=Summary of updates= | =Summary of updates= | ||
Latest revision as of 10:02, 1 February 2012
Summary of updates
All outstanding major DELL firmware and ESX patches as of December 2008...
- DELL Firmware Updates
- PERC v5.2.2-0072
- BMC v2.37
- BIOS v2.5.0
- NIC FW v4.4.2
- DRAC v1.4
- ESX software v3.5 update 3
- ESX software patches included in "RTS ESX baseline (Dec 08)"
- ESX350-200811401-SG Updates VMkernel, hostd, and Other RPMs
- ESX350-200811406-SG Security Update to bzip2
- ESX350-200811402-SG Updates ESX Scripts
- ESX350-200811405-SG Security Update to libxml2
- ESX350-200811409-BG Updates Kernel Source and VMNIX
- ESX350-200811408-BG Updates QLogic Software Driver
Full upgrade procedure
Useful Unix commands, not specifically required, but may be of use - General Unix
PROCEDURE NOT COMPLETED YET
Prep for updates
- Ensure that ESX already has ESX350-200808202-UG Update to ESX Scripts applied, otherwise UpdateManager will apply every update it can find (rather than just what is in the baseline)
- Put ESX into Maintenance Mode
- If a stand-alone ESX, all VM's will need to be shutdown
- If a cluster ESX, all VM's should be VMotion'ed to alternative ESX's
Apply DELL firmware updates
- Putty onto ESX, login as simons
- Sudo as root
su -
- Move into home directory
cd /home/simons
- Make updates executable
chmod +x *.BIN
- Apply updates using following commands in order indicated. Do not boot until completion of last update.
- 1950 Only
./RAID_FRMW_LX_R189337.BIN
./BMC_FRMW_LX_R202156.BIN
./NETW_FRMW_LX_R197246.BIN
./PE1950_BIOS_LX_2.5.0.BIN
./RAC_FRMW_LX_R197962.BIN
- 2950 Only
./RAID_FRMW_LX_R189337.BIN
./BMC_FRMW_LX_R202152.BIN
./NETW_FRMW_LX_R197246.BIN
./PE2950_BIOS_LX_2.5.0.BIN
./RAC_FRMW_LX_R197962.BIN
- 1950 Only
Apply ESX patches
- Run up Virtual Infrastructure client and ensure you've the right version installed...
- Help | About... Client should be v2.5.0 build 84767
- If not, browse to uklonvcp1 and install new version
- Help | About... Client should be v2.5.0 build 84767
- Ensure you've got the Update Manager plug-in installed and enabled
- Plugins | Manage Plugins.., Available tab: Update Manager should be installed
- Installed tab, Update Manager should be enabled
- Highlight the ESX, righ-click and select Scan for updates
- Once the scan has completed go to the Update Manager tab
- Right-click over the "RTS ESX baseline (8 Dec 08)" baseline and select Remediate
- VC will scan the ESX's, then push out all applicable update, then reboot the ESX
Tidy Up
- Show disk usage (note for later comparison)
df -h
- Delete files...
rm -f *.BIN
- Show disk usage (should have reduced from earlier check)
df -h
Final checks
- Ensure all applicable software is started on VM's
- Ensure no alarms on Netcool for affected VM's or ESX's