Installation (ESX)
Jump to navigation
Jump to search
Password Complexity Override
In order to be able to change a user (or root) password to one that breaches password complexity checking
- Disable PAM module
esxcfg-auth --usepamqc -1 -1 -1 -1 -1 -1
- Disable complexity checker
esxcfg-auth --usecrack -1 -1 -1 -1 -1 -1
- Change password
- Re-enable PAM module
esxcfg-auth --usepamqc=-1 -1 -1 -1 8 8
HBA and SAN Operations
HBAnywhere Installation
- Download the Driver and Application kit for VMware from Emulex's website.
- At time of writing the current version of package was
elxvmwarecorekit-esx35-4.0a45-1.i386.rpm
- At time of writing the current version of package was
- Copy the package to the server
- EG
pscp -pw [password] elxvmwarecorekit-esx35-4.0a45-1.i386.rpm platadmn@dtcp-esxsvce01a:/home/platadmn
- EG
- Install the package
- EG
rpm -ivh elxvmwarecorekit-2.1a42-1.i386.rpm
- EG
HBA Firmware Upgrade
Requires HBAnywhere to be installed 1st, see HBAnywhere Installation for further info.
- Download the correct firmware version from Emulex's website
- EG for LPe11002's
- Extract, and copy file to server
- Find adapter's WWPN's
- EG
/usr/sbin/hbanyware/hbacmd ListHBAs
- EG
- Download new firware version to each HBA
- EG
/usr/sbin/hbanyware/hbacmd download 10:00:00:00:c9:82:97:9e zf280a4.all
- EG
EMCgrab Collection
- Download correct verion from EMC's website
- At time of writing the current version file was emcgrab_ESX_v1.1.tar
- Copy to server
- EG
pscp emcgrab_ESX_v1.1.tar platadmn@dtcp-esxsvce02a:/home/platadmn
- EG
- Uncompress the file
- EG
tar -xvf emcgrab_ESX_v1.1.tar
- EG
- Run grab (can take a few minutes, best done out of hours)
- EG
./emcgrab.sh
- EG
- Results can be found in
\emcgrab\outputs
folder
Vmkernel Log Analysis
Storage Monitor Log Entries
How to decode the following type of entries...
Sep 3 15:15:14 tfukesxent1 vmkernel: 85:01:23:01.532 cpu4:2264)StorageMonitor: 196: vmhba1:2:0:0 status = 2/0 0x6 0x2a 0x1 Sep 3 15:15:32 tfukesxent1 vmkernel: 85:01:23:19.391 cpu4:2253)StorageMonitor: 196: vmhba1:3:9:0 status = 2/0 0x6 0x2a 0x1
The status message consists of the follow four decimal and hex blocks...
Device Status / Host Status | Sense Key | Additional Sense Code | Additional Sense Code Qualifier |
Where the ESX Device and SAN host status' mean...
Decimal | Device Status | Host Status |
---|---|---|
0 | No Errors | Host_OK |
1 | Host No_Connect | |
2 | Check Condition | Host_Busy_Busy |
3 | Host_Timeout | |
4 | Host_Bad_Target | |
5 | Host_Abort | |
6 | Host_Parity | |
7 | Host_Error | |
8 | Device Busy | Host_Reset |
9 | Host_Bad_INTR | |
10 | Host_PassThrough | |
11 | Host_Soft_Error | |
24 | Reservation Conflict |
Where the Sense Key mean...
Hex | Sense Key |
---|---|
0x0 | No Sense Information |
0x1 | Last command completed but used error correction |
0x2 | Unit Not Ready |
0x3 | Medium Error |
0x4 | Hardware Error |
0x5 | ILLEGAL_REQUEST (Passive SP) |
0x6 | LUN Reset |
0x7 | Data_Protect - Access to data is blocked |
0x8 | Blank_Check - Reached an unexpected region |
0xa | Copy_Aborted |
0xb | Aborted_Command - Target aborted command |
0xc | Comparison for SEARCH DATA unsuccessful |
0xd | Volume_Overflow - Medium is full |
0xe | Source and Data on Medium do not agree |
The Additional Sense Code and Additional Sense Code Qualifier mean
Hex | Sense Code |
---|---|
0x4 | Unit Not Ready |
0x3 | Unit Not Ready - Manual Intervention Required |
0x2 | Unit Not Ready - Initializing Command Required |
0x29 | Device Power on or SCSI Reset |