VCP4
Other Resources
Plan, Install and Upgrade VMware ESX/ESXi
Install VMware ESX/ESXi on local storage
Minimum Hardware Requirements
- 64bit CPU (AMD Opteron, Intel Xenon [inc Nahalem])
- CPU Virtualisation features required to support 64bit VM's
- 2GB RAM
- 1+ NIC
- SCSI, Fibre Channel or Internal RAID controller
- LUN, SAS or SATA (SATA must be connected through a SAS controller)
Notes
- ESX's hardware clock should be set to UTC
- IPv6 not supported during installation
ESXi Specifics
- All blank internal disks are formatted with VMFS (except 4GB VFAT scratch/swap partition, used for vm-support dumps)
- Direct Console is used to
- Configure host defaults
- Set-up administrator access
- Troubleshoot
- If no DHCP found during install, default 169.254.0.0 / 16 address assigned
vSphere Editions
Edition | Features |
---|---|
Essentials | 6 cores/CPU, 4way vSMP, 256GB/ESX, VC Agent, Update Manager, VMsafe, vStorage API's |
Essentials Plus | Essentials + Data Recovery |
Standard | Essentials + HA |
Advanced | Standard + 12 cores/CPU, Hot Add, FT, vShield, VMotion, Data Recovery |
Enterprise | Advanced + 6 cores/CPU, Storage vMotion, Data Recovery, DRS |
Enterprise Plus | 12 cores/CPU, 8way vSMP, maxGB/ESX, vNetwork Distributed Switch, Host Profiles, 3rd Party Multipathing |
vCentre Foundation | Fully featured, but limited to managing 3 ESX's |
Upgrade VMware ESX/ESXi
Pre-Upgrade Backups
- Backup ESX Host Config
- Back up the files in the
/etc/passwd
,/etc/groups
,/etc/shadow
, and/etc/gshadow
directories (shadow dir's may not exist). - Backup any custom scripts
- Backup any
.vmx
files - Backup any local images etc on local VMFS
- Back up the files in the
- Backup ESXi Host Config
- Use vSphere CLI to run
vicfg-cfgbackup --server <ESXi-host-ip> --portnumber <port_number> --protocol <protocol_type> --username username --password <password> -s <backup-filename>
- Use vSphere CLI to run
- VM backup
- Snapshot before upgrade
Upgrade Scenarios
Method | Notes |
---|---|
with Host Clusters | Use Update Manager. Upgrade VC, Update Manager, ESX, VM, licenses |
without Host Clusters | Use vSphere Host Update Utility (good for estates < 10 ESX's), runs from VC Client |
vMotion | Migrate VM's from ESX v3 to v4, then perform required VM upgrade |
Upgrade vMotion | When upgrading from ESX v2, VM's are migrated from VMFS v2 to v3 and upgraded |
Cold migration (with VC) | Move VM's through VC to v4 ESX's and power-up, then upgrade VM |
Cold migration (without VC) | Manually move VM's to v4 ESX's and power-up, then upgrade VM |
VC on new machine | Backup DB, copy across SSL folder to new machine, run install |
ESX/ESXi Upgrade
- DHCP not recommended
- Limited support for v2.5.5, all later versions fully supported
- Need to specify a local VMFS for Service Console VM (not ESXi)
Rollback
- ESX
- Run
rollback-to-esx3
command in Service Console, delete ESX v4 Service Console following restart - Restore backed up files
- Run
- ESXi
- During boot, press Shift + R to boot into the Standby (ESX3) build
- Restore backup using
vicfg-cfgbackup -l
Secure VMware ESX/ESXi
Install VMware ESX/ESXi on SAN Storage
Identify vSphere Architecture and Solutions
Platforms
- vSphere 4
- Server
- ESXi (standalone, free)
Datacentre Solutions
- View - (VDI) Desktop virtualisation
- SRM - Site Recovery Manager, automate site fail-over/recovery, DR management
- Lab Manager - VM manager for developers, allows dev's to rapidly deploy VM images for testing etc
- Stage Manager - Being consolidated into Lab Manager
Configure ESX/ESXi Networking
Configure Virtual Switches
Nothing new !!
Configure vNetwork Distributed Switches
- dvSwitch - Distributed Virtual Switch (DVS) which spans numerous ESX's
- dvPort - A dvSwitch Service Console, VMkernel, or VM Port Group port
- CDP is enabled in the Advanced Settings of the dvSwitch
VLAN Options
- None - Straight-through connected switch
- VLAN - Traditional single VLAN assignment to a port group
- VLAN Trunking - Multiple VLAN's can be assigned to a dv Port Group
- Private VLAN - Allows Private VLANs (see http://en.wikipedia.org/wiki/Private_VLAN)
Configure VMware ESX/ESXi Management Network
Configure ESX/ESXi Storage
Configure FC SAN Storage
PSA - Pluggable Storage Architecture
- Manages storage multipathing
- Allows simultaneous operation of multiple multipathing plugins (MPPs)
- Native Multipathing Plugin (NMP) provided by default, can have sub-plugins (can be either VMware or 3rd party)
- Storage Array Type Plugin (SATP) - unique to a particular array (effectively an array driver, like a standard PC hardware driver)
- Path Selection Plugin (PSP)
- Multipathing Plugin (MPP) - 3rd party, can run alongside or in addition to Native Multipathing Plugin
PSA operations
- Loads and unloads multipathing plugins
- Hides VM specifics from a particular plugin
- Routes I/O requests for a specific logical device to the MPP managing that device
- Handles I/O queuing to the logical devices
- Implements logical devices bandwidth between VM's
- Handles I/O queueing to the physical storage HBA's
- Handles physical path discovery and removal
- Provides logical device and physical path I/O stats
MPP / NMP operations
- Manage physical path (un)claiming
- Manage creation, and (de)registration of logical devices
- Associate physical paths with logic volumes
- Process I/O requests to logical devices
- Select an optimal physical path for the request
- Depending on storage device, perform specific actions necessary to handle path failures and I/O cmd retries
- Support management tasks, EG abort or reset of logical devices
PSA Claim Rules Used to define paths should be used by a particular plugin module
LUN Masking Used to prevent an ESX from seeing LUN's or using individual paths to a LUN Add and load a claim rule to apply
Configure iSCSI SAN Storage
Configure NFS Datastores
- ESX's manage exclusive access to files via
.lc-XXX
lock files
Configure and Manage VMFS Datastores
- VMFS Datastore capacity can be increased on the fly whilst VM's are running (from that datastore)
Install and Configure vCenter Server
Install vCenter Server
Minimum Requirements
- 2x CPU's (2GHz)
- 3GB RAM
- 2GB disk
- Microsoft SQL2005 Express
Scale | VC | CPU | Memory |
---|---|---|---|
50 ESXs, 250 VMs | 32 bit | 2 | 4 GB |
200 ESXs, 2000 VMs | 64 bit | 4 | 4 GB |
300 ESXs, 3000 VMs | 64 bit | 4 | 8 GB |
- Database must be 32bit only, regardless of VC's OS (default database on 64bit SQL is 64bit)
Manage vSphere Client plug-ins
Plug-In | Description |
---|---|
Update Manager | |
Converter Enterprise | |
vShield Zones | App aware firewall, inspects client-server and inter-VM traffic to provide traffic analysis and app-aware firewall partitioning |
Orchestrator | Workflow engine to manage automated tasks/workflows |
Data Recovery | Backup and recovery. Centralised management of backup tasks (inc data de-duplication). |
Configure vCenter Server
Guest Customisation Requirements
- Source machine must have
- VMTools installed (latest version)
- Similar OS to intended new machine
- SCSI disks
- (Win) Guest OS cannot be a domain controller
- (Win) Sysprep must be installed on VC
- (Linux) Guest OS must have Perl installed
Configure Access Control
Role | Type | ESX / VC | Description |
---|---|---|---|
No Access | System | ESX & VC | No view or do. Can be used to stop permissions propagating. |
Read Only | System | ESX & VC | View all except Console, no do. |
Administrator | System | ESX & VC | Full rights |
VM User | Sample | VC only | VM start/stop, console, insert media (CD) |
VM Power User | Sample | VC only | As user plus hardware and snapshot operations |
Resource Pool Admin | Sample | VC Only | Akin to an OU admin, full rights for child objects
Cannot create new VM's without additional VM and datastore privileges. |
VCB User | Sample | VC Only | Expected to be used by VCB, do not modify! |
Datastore Consumer | Sample | VC Only | Allows creation of VMDK's or snapshots in datastore (additional VM privileges to action) |
Network Consumer | Sample | VC Only | Allows assignment of VM's to networks (additional VM privileges to action) |
Deploy and Manage Virtual Machines and vApps
Create and Deploy Virtual Machines
- VM Hardware v4 runs on ESX3 or ESX4, v7 runs on ESX4 only
- VM's running MS Windows should have SCSI TimoutValue changed to 60 secs to allow Windows to tolerate delayed SAN I/O from path failovers
Disk Types
- Thick - traditional (can convert to Thin via Storage vMotion)
- Thin - minimal space usage (conversion to Thick is manual process)
SCSI Controller Types
- BusLogic Parallel
- LSI Logic SAS
- LSI Logic Parallel
- VMware Paravirtual
- High performance to provide better throughput with lower ESX CPU usage
- Only VM h/ware v7 with Win2k3, Win2k8 or Red Hat Ent v5
- Not supported with
- Boot disks (use a standard adapter for VM's OS/boot disk)
- Record/replay
- Fault Tolerance
- MSCS Clustering (so also SQL clusters)
N-port ID virtualization (NPIV)
- Provides VM's with RDM's unconstrained to an ESX (ie allows VMotion when using RDM's)
- Must be enabled on SAN switch
- ESX's HBA's must support NPIV
- NPIV enabled VM's are assigned 4 NPIV WWN's
vNICs
- Flexible - Becomes VMXNET when on 32bit OS with VMTools installed (VMware optimised), otherwise vLANCE (old AMD LANCE 10MB NIC driver)
- e1000 - Default for 64bit OS's, emulates an Intel E1000 card
- VMXNET2 - Aka enhanced VMXNET, supports jumbo frames and TSO, limited OS support
- VMXNET3 - Performance driver, only supported on VM hardware v7, and limited OS's
Manage Virtual Machines
VM hardware can be modified in-flight as long as
- The guest OS supports hot plug (eg Win2008)
- VM hardware version is v7
- vCPU's can only be added if "CPU Hot Plug" is enabled in the VM's options
Deploy vApps
Deploying an OVF template
- Non-OVF format appliances can be converted using the VMware vCentre Converter module
- During deployment IP allocation can be (if OVF templates states this is configurable)
- Fixed
- Transient - VCentre manages a pool of available IP's
- DHCP
vApp - An enhanced resource pool to run a contained group of VM's
Manage Compliance
Install, Configure and Manage VMware vCenter Update Manager
- Update Manager can be installed on VC, recommended separate for large environments
- Requires its own db instance (can be on same server as VC database, recommended separate)
- Requires sysadmin or db_owner role
- VMware vCenter Update Manager Guest Agent is installed to Win or Linux guests on 1st patch scan or remediation run.
- Smart Rebooting - Update manager attempts to adhere to the startup dependencies stated in a vApp config
- Edit
vci-integrity.xml
to change<patchStore>
- Location of downloaded patches (default -C:\Documents and Settings\All Users\Application Data\VMware\VMware Update Manager\Data\
<PatchDepotUrl>
- URL used by ESX's to access patches (default - Update Manager server)
Establish and Apply ESX Host Profiles
- Used to ensure consistent configuration across ESX's
- Create a profile from a reference ESX, then apply to Cluster or ESX
- Reference ESX can be changed
- Profile can be refreshed (if reference ESX config has been updated)
Establish Service Levels
Create and Configure VMware Clusters
VM Monitoring
- HA monitors VM to detect if they've hung / stopped responding, and resets VM if both
- VM Tools heartbeat lost in interval
- No VM I/O in interval (default 120 secs, reconfig at cluster level
das.iostatsInterval
- Default 60 secs no h/beat, max 3 resets in 24 hrs (High sensitivity 30 secs and 1hr, Low 120 secs and 7 days)
- VM Monitoring should be suspending during network changes
High Availability
- Uses the following networks for HA communication
- ESX - All Service Console networks
- ESXi - All VMkernel networks (not VMotion network if alternatives available)
Distributed Power Management
- Uses current load and VM resource reservation to calculate required number of powered-up ESXs
- ESX power-on achieved by WOL, IPMI or iLO
- IMPI or iLO: Must specify IP, MAC etc for each ESX
- WOL: VMotion NIC must support WOL, and VMotion switchport must be set to Auto (as WOL often not supported by NIC at 1GB)
- Must test ESX in and out of Standby Mode before enabling DPM
Enhanced VMotion Compatibility
- Hides additional CPU features in a cluster (ie features one ESX in a cluster has but another doesn't)
- Requires no VM's to be running on the cluster (as the CPU type will effectively be changed)
- Generally works for similar manufacture make & model CPU's with different stepping levels
Enable a Fault Tolerant Virtual Machine
- vLockstep - Keeps Primary and Secondary VM's in sync
- On-Demand Fault Tolerance - Temporary FT, configured for a VM during a critical time
Prerequisites
- Cluster
- HA and host monitoring must be enabled
- Host certificate checking must be enabled
- ESX's
- Separate VMotion and FT Logging NIC(s) configured (should be different subnets for each)
- Same ESX software version and patch level (FT must be temporarily disabled during ESX software upgrades)
- FT-compatible processor
- Host certified by OEM as FT-capable
- Host BIOS must have Hardware Virtualisation (eg Intel VT) enabled
- VM's
- VMDK files must be thick provisioned with Cluster Features enabled
- Run supported OS (generally all, may require reboot to enable FT)
Unsupported
- Snapshots (must be removed/committed before FT enabled)
- Storage VMotion
- DRS
- SMP - Only single vCPU supported
- Physical RDM
- CD-ROM or Floppy media/ISO not on shared storage
- Paravirtualised guests
- NPIV
- NIC Passthrough
Setup
- Enable host certificate checking
- Configure VMkernel networking
- Create HA Cluster and perform Profile Compliance
- Turn on FT for appropriate VM's
Create and Configure Resource Pools
Nothing new!
Migrate Virtual Machines
- Cold Migration - VM is powered off, can be migrated to another datacentre
- Suspended VM Migration - Config and disk files can be relocated, can be migrated to another datacentre
- VMotion - VM is powered on. Moves VM, config and disk files are static
- Storage VMotion - VM is powered on. VM is static, config and disk files move